The short answer
Start with the simple things: check the controller isn't in holiday or hot water mode, the system pressure hasn't dropped, the power is on and the outdoor unit isn't blocked or iced up.
If those all look right, the most common causes are low water pressure, air or a blocked filter restricting the flow, incorrect control settings, or a fault on the refrigeration side. These need an engineer to diagnose properly.
Checks to try first
Before calling an engineer, a few quick checks can rule out the simple causes:
- 01Controller modeMake sure the heat pump isn't in holiday, standby or hot water only mode, and that heating is switched on.
- 02Room thermostats and schedulesCheck the set temperatures and time schedules haven't been changed, especially after a power cut or software update.
- 03PowerCheck the isolator next to the outdoor unit is on and nothing has tripped in your consumer unit.
- 04System pressureLook at the pressure gauge. If it's well below what's normal for your system (often around 1 bar when cold), the system may need topping up or have a leak.
- 05Error codesNote any code on the controller. It tells an engineer a lot before they arrive.
- 06Outdoor unitMake sure it isn't blocked by leaves, snow, furniture or plants, and that ice is clearing after defrost cycles.
If something has tripped repeatedly or the pressure keeps dropping, don't keep resetting it. That's a sign of an underlying fault.
The most common causes we find
- Low system pressure: caused by a small leak, a faulty pressure relief valve or an expansion vessel that has lost its charge.
- Restricted flow: air in the system, a blocked strainer or magnetic filter, or a partly closed valve reduces the flow the heat pump needs.
- Control settings: a weather compensation curve set too low, the wrong flow temperature or a schedule that doesn't give the house time to warm up.
- Diverter valve faults: if the valve sticks in the hot water position, the heating won't get any heat.
- Defrost problems: a blocked coil, poor airflow or a failed sensor can stop ice clearing, which cuts the heat output.
- Refrigeration faults: a refrigerant leak, a failing expansion valve or compressor problems. These need an F-Gas certified engineer.
- Sensor, pump or electrical faults: a failed temperature sensor, circulating pump or control board component.
Sometimes the system was never designed properly: radiators too small for low flow temperatures, or a heat pump sized without a proper heat loss calculation. We can check the design as well as the fault. See our commissioning and optimisation service.
What's normal for a heat pump
Heat pumps heat differently from a gas or oil boiler, so some things that feel wrong are completely normal:
- Radiators feel warm rather than hot, because the water runs at a lower temperature.
- Rooms heat up more slowly, and the system works best running steadily rather than in short bursts.
- The outdoor unit may steam, go quiet or stop the fan for a few minutes during a defrost.
- The heat pump can run for long periods in cold weather. That's how it stays efficient.
If your home is reaching the temperature you set, longer run times usually aren't a problem. If it isn't reaching temperature, or your bills have jumped, it's worth getting it checked.
When to call an engineer
- The house isn't reaching temperature after the checks above.
- The pressure keeps dropping, or there's water around pipes or valves.
- An error code keeps coming back, or the isolator or breaker keeps tripping.
- Ice builds up on the outdoor unit and doesn't clear.
- You hear new grinding, rattling or loud humming noises.
We diagnose and repair air source and ground source heat pumps, including systems other installers couldn't fix. See our repairs and fault finding service, or read how often a heat pump should be serviced to help prevent problems.